MAKELSAN PM SERIES MODULAR UPS 10-1560 kVA

(Three Phase / Three Phase)

High Performance, Modular 3-Phase Power Protection Scalable up to 1800kVA, With 95.5% High Efficiency for High Density Data Centers and Critical Applications

 • Full IGBT Double Conversion Technology
 • Perfect Generator Compatibility
 • Separated Bypass
 • Optional External Battery Quantity (16-20 pcs)
 • Remote EPO/EPO Function
 • Common Battery
 • Control Monitoring with 5" Color Touch-Screen LCD Graphic Display
 • Control of On/Off State of Each Module
 • Superior MTBF and MTTR
 • Freely Set The Charge Current
 • Intelligent Charging
 • Super-large LCD Display (With Touchable Screen)
 • Single Module LCD Display
 • Mid or Small Power Distributing System
 • Easy Maintenance

Technical Specifications

  Model PM 3300-100kVA PM 3320-200kVA PM 3300-250kVA PM 3300-300kVA PM 3340-520kVA
  Capacity          
  UPS Cabinet 10~100kVA 20~200kVA 25~250kVA 30~300kVA 40~520kVA
  Paralleling Up to 6 Frame Up to 6 Frame Up to 6 Frame Up to 6 Frame Up to 4 Frame
  Maksimum Güç 600kW 1200kW 1500kW 1800kW 2080kW
  PM Module 10kVA/10kW, 15kVA/15kW, 20kVA/20kW, 25kVA/25kW, 30kVA/30kW, 40kVA/40kW
  Input  
  Phase 3 Phase 4 Wires and Ground
  Rated Voltage 380/400/415 VAC
  Voltage Range 208~478VAC or 120VAC~276VAC
  Frequency Range (Hz) 40~70Hz
  Power Factor >0.99
  Bypass Voltage Range Max. Voltage: +15% (Optional +5%, +10%, +25%) Min. Voltage: -45% (Optional -20%, -30%)
  Frequency protection range: ±10%
  Current Harmonic <2% (100% non-linear load)
  Generator Input Support
  Output  
  Phase 3 Phase 4 Wires and Ground
  Rated Voltage 220/230VAC 380/400/415VAC
  Power Factor 1
  Voltage Precision ±%1
  Output Frequceny ±1%,±2%,±4%,±5%,±10% of the rated frequency (Optional) (50/60±0.2)Hz
  Crest Factor 3:1
  THD ≤%1 With Linear Load ≤%4 With Non-Linear Load
  Efficiency %95.5
  Communication  
  UPS Cabinet RS232, RS485, Intelligent Slot x 2 (SNMP Card, Relay Card, Dry Contact Optional)
  Interface  
  PM Series UPS Module RS232
  Battery  
  Voltage ±192V / ±204V / 216V ± / 228V / ± 240V DC; Battery Quantity(Optional)
  Charge Current (A) UPS Cabinet 18A Max 30A Max 60A Max 100A Max 130A Max
  Module 6A/10A/(20A Optional) Max (Charge Current Can be Set According to Battery Capacity Installed)
  Backup Time Depends on the Capacity of External Batteries
  Transfer Time Utilty to Battery : 0ms; Utily to bypass: 0ms
  Protection  
  Overload Normal Mode Load ≤110%: Last 60min, ≤125%: Last 10min, ≤150%: Last 1min, ≥150% Shut Down UPS Immediately
  Battery Mode Load ≤110%: Last 10min, ≤125%: Last 1min, ≤150%: Last 1s ≥150% Shut Down UPS Immediately
  By-pass Mode Breaker (10kVA: 20A / 15kVA: 32A / 20kVA: 40A / 25kVA: 40A/ 30kVA: 40A)
  Operating  
  Temperature 0°C ~ 40ºC
  Environment  
  Humidty 0 ~ %95 non condensing
  Storage Temperature -25ºC ~ 55ºC
  Noise Number of Modules≤5 <55dBA (1m)
  Number of Modules ≥5 <65dBA (1m)
  Altitude <1500m
  Dimensions  
  Unit Dimensions
(WxDxH) (mm)
UPS Cabinet 600 x 840 x 1400 600 x 1100 x 2000 1200x860x2000
  Module 443 x 580 x 131 (3U)
  Weight (kg) UPS Cabinet 170 270 275 280 514
  Module 10kVA: 26kg; 15kVA: 30kg; 20kVA: 31kg; 25kVA: 31kg; 30kVA: 32kg; 40kVA:33kg
  Industry Standard CE,EN/IEC 62040-2, EN/IEC 62040-1, EN/IEC 62040-3
  Makelsan reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Makelsan products previously or subsequently sold. Makelsan does not guarantee the items of the accuracy and completeness.
  Model PM 3340-800kVA PM 3340-1040kVA PM 3340-1540kVA
  Capacity      
  UPS Cabinet 800kVA 1040kVA 1560kVA
  Paralleling Up to 2 Frame Up to 2 Frame Up to 1 Frame
  Maksimum Güç 1440kW 2080kW 1404kW
  PM Module 10kVA/10kW, 15kVA/15kW, 20kVA/20kW, 25kVA/25kW, 30kVA/30kW, 40kVA/40kW
  Input  
  Phase 3 Phase 4 Wires and Ground
  Rated Voltage 380/400/415 VAC
  Voltage Range 208~478VAC or 120VAC~276VAC
  Frequency Range (Hz) 40~70Hz
  Power Factor >0.99
  Bypass Voltage Range Max. Voltage: +15% (Optional +5%, +10%, +25%) Min. Voltage: -45% (Optional -20%, -30%)
  Frequency protection range: ±10%
  Current Harmonic <2% (100% non-linear load)
  Generator Input Support
  Output  
  Phase 3 Phase 4 Wires and Ground
  Rated Voltage 220/230VAC 380/400/415VAC
  Power Factor 1
  Voltage Precision ±%1
  Output Frequceny ±1%,±2%,±4%,±5%,±10% of the rated frequency (Optional) (50/60±0.2)Hz
  Crest Factor 3:1
  THD ≤%1 With Linear Load ≤%4 With Non-Linear Load
  Efficiency %95.5
  Communication  
  UPS Cabinet RS232, RS485, Intelligent Slot x 2 (SNMP Card, Relay Card, Dry Contact Optional)
  Interface  
  PM Series UPS Module RS232
  Battery  
  Voltage ±192V / ±204V / 216V ± / 228V / ± 240V DC; Battery Quantity(Optional)
  Charge Current (A) UPS Cabinet 200A Max 260A Max 390A Max
  Module 6A/10A/(20A Optional) Max (Charge Current Can be Set According to Battery Capacity Installed)
  Backup Time Depends on the Capacity of External Batteries
  Transfer Time Utilty to Battery : 0ms; Utily to bypass: 0ms
  Protection  
  Overload Normal Mode Load ≤110%: Last 60min, ≤125%: Last 10min, ≤150%: Last 1min, ≥150% Shut Down UPS Immediately
  Battery Mode Load ≤110%: Last 10min, ≤125%: Last 1min, ≤150%: Last 1s ≥150% Shut Down UPS Immediately
  By-pass Mode Breaker (10kVA: 20A / 15kVA: 32A / 20kVA: 40A / 25kVA: 40A/ 30kVA: 40A)
  Operating  
  Temperature 0°C ~ 40ºC
  Environment  
  Humidty 0 ~ %95 non condensing
  Storage Temperature -25ºC ~ 55ºC
  Noise Number of Modules≤5 <55dBA (1m)
  Number of Modules ≥5 <65dBA (1m)
  Altitude <1500m
  Dimensions  
  Unit Dimensions
(WxDxH) (mm)
UPS Cabinet 860 x 3000 x 2000 1100 x 4800 x 2000
  Mo