menu
UP

Inabikari Split-type DC Charging Equipment

Split-type DC charging equipment is used for electric vehicle charging power supply of centralized charging network. It can deploy charging network rapidly and effectively, providing high-power charging service for electric vehicles. It consists of rectifier cabinet and outdoor charging terminals. Each rectifier cabinet can be installed maximum 14pcs rectifier modules. It is applicable to charging stations and enterprises’ parking lot. Split-type DC charger I: Output voltage range DC 200 V ~ 500 V adjustable, the maximum output power of single unit is 210KW. Split-type DC charger II: Output voltage range DC 300 V ~ 750 V adjustable, the maximum output power of single unit is 210KW.

Characteristics

  • Modular design meets different capacity requirement, and rectifier modules with three-phase active APFC dynamic regulation module having excellent airduct design, and realizes integrated protection for rectification, control, output and measurement etc.
  • Superior protection includes AC overvoltage / under voltage, output overvoltage / undervoltage, overcurrent, short-circuit, overtemperature, overload, reverse-battery, inrush current surge protections etc. dule having excellent airduct design, and realizes integrated protection for rectification, control, output and measurement etc.

Technical Specifications

MODEL

EVDC-210KW-5
EVDC-210KW-7

INPUT

Input voltage

260 V ~ 456 V (three phase five wire)

Input current

≤ 360 A

AC input frequency

45 Hz ~ 65 Hz

Efficiency

≥ 95%

Power factor

≥ 0.99

Input THD

≤ 5%

OUTPUT

Output voltage range

500 Vdc series: 200 V ~ 500 V
700 Vdc series: 300 V ~ 750 V

Rated output current (500 V)

420 V

Rated output current (700 V)

280 V

Max. output current (500V)

504 V

Max. output current (700V)

336 V

Soft start time

3 s ~ 8 s

Output constant-current range

10% ~ 100%

Voltage regulation accuracy

≤ ± 0.2%

Current regulation accuracy

≤ ± 0.5%

Ripple coefficient (peak value)

≤ 1%

Current-sharing unbalanced degree

≤ ±3% (50% ~ 100% rated load)

Noise

< 65 dB

PROTECTIONS

Output short-circuit protection

Retraction current ≤ 40% Io; auto-restorable

Output overvoltage protection

No output after protection;
non-restorable (require manual restoring)

Input over / undervoltage protection

No output after protection; auto-restorable

Phase-lack protection

No output after protection; auto-restorable

Overtemperature protection

No output after protection; auto-restorable

CHARGING CONFIGURATION AND STANDARD

Charging plug number

/

Charging cable length (m)

/

Communication protocol standard

GB/T 27930-2015

Charger standard

GB/T 18487.1-2015, GB/T 20234.1-2015, GB/T 20234.3-2015, NB/T 33001-2010, NB/T 33008.1-2013

OTHERS

Operating  temperature

-20℃ ~ + 50℃

Storage temperature

-40℃ ~ + 80℃

Relative humidity

≤ 95%

Atmospheric pressure

70 kPa ~ 106 kPa

IP rating

IP31

Dimensions (H × W × D) (mm)

2000 × 600 × 600

Weight (kg)

≤ 270